Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
RGO (Porto Alegre) ; 61(3): 383-388, jul.-set. 2013.
Article in English | LILACS | ID: lil-691755

ABSTRACT

Head and neck cancer is considered a public health problem worldwide, given its high morbidity and mortality. The more advanced is the histopathologic grade, the more aggressive may be the therapies. The development of health policies, diagnosis and treatments lead to better prognostic perspectives. This paper aimed to review the literature regarding the application of positron emission tomography in headand neck cancer, including its impact in the diagnosis, image principles, radiotracers, positron emission tomography / computed tomographyimage fusion and other advantages. The review was performed following systematized search strategies reported in the literature. It could be observed that the use of positron emission tomography improves the diagnostic approach of the patients, especially when positron emission tomography is allied to computed tomography. As it provides physiological information, positron emission tomography also benefits the prognostic and reduces the morbidity related to the treatment of head and neck cancer.


Apresentando-se como um problema de saúde pública em todo o mundo, o câncer de cabeça e pescoço caracteriza-se por sua alta morbidadee mortalidade. Quanto mais avançado o grau de diferenciação tumoral, mais mutiladoras tendem a ser as terapias empregadas. Desta forma,os avanços nos âmbitos da promoção de saúde, diagnóstico e tratamento são extremamente benéficos ao prognóstico. Esta revista daliteratura tem por objetivo discorrer sobre a aplicação da tomografia por emissão de pósitrons no diagnóstico e planejamento terapêuticode pacientes portadores de tumores malignos de cabeça e pescoço, princípios de formação da imagem, radiofármacos utilizados, fusãode imagens tomografia por emissão de pósitrons e tomografia computadorizada e suas contribuições. O levantamento bibliográfico foiefetuado segundo estratégias sistematizadas relatadas em literatura. Fornecendo informações relativas à fisiologia das lesões através daadministração de radiofármacos, pode ser observado que a tomografia por emissão de pósitrons, especialmente quando aliada à tomografiacomputadorizada, maximiza as possibilidades diagnósticas em determinadas indicações, favorecendo ao prognóstico e sugerindo redução na morbidade decorrente do tratamento no câncer de cabeça e pescoço.


Subject(s)
Humans , Carcinoma, Squamous Cell , Head and Neck Neoplasms , Positron-Emission Tomography
2.
Article in Portuguese | LILACS, BBO | ID: lil-673929

ABSTRACT

Objetivo: Analisar os achados tomográficos fortuitos em seios maxilares por meio de exames de Tomografia Computadorizada por Feixe Cônico, bem como sua correlação com a sintomatologia clínica relatada. Método: Exames da maxila de 54 pacientes foram avaliados por dois examinadores independentes considerando os seios maxilares direito e esquerdo (n=108). Foi verificada a ocorrência de patologias sinusais nas paredes anterior, medial, lateral e posterior, assoalho e teto dos seios maxilares, utilizando o software i-CAT Vision® (versão 1.6.20). Esses dados foram correlacionados com a presença ou ausência de sintomatologia relacionada à patologia sinusal. Resultados: O achado tomográfico mais observado foi a opacificação do seio pelo acúmulo de secreções (28,70%), seguido pelo espessamento da mucosa antral do seio maxilar (20,37%) e pela presença de cisto mucoso (17,59%). Em 60,22% dos casos não houve relato de sintomatologia clínica, independente da presença de patologias. A ocorrência de sintomatologia e achados tomográficos concomitantemente foi observada em 35,20% dos seios examinados, enquanto em 45,37% o achado tomográfico estava presente, sem, contanto, haver relato de sintomatologia. As paredes dos seios mais afetadas foram o assoalho (71,30%), correlacionando fator odontogênico associado, e a parede medial (57,40%), estando relacionada à frequência de infecções das vias aéreas superiores. O protocolo de visualização multiplanar obteve total acurácia e sensibilidade (100%), seguido pelos protocolos coronal (81,50%), e axial (76%).Conclusão: O exame de Tomografia Computadorizada por Feixe Cônico mostrou- se útil para definir a presença de patologias sinusais, porém é inespecífico na correlação dos achados em pacientes sintomáticos e na intensidade destes sintomas.


Objective: To analyze the eventual tomographic findings in maxillary sinuses by cone beam computed tomography as well as its relationship with the reported clinical symptoms. Method: Maxillary exams of 54 patients were evaluated by two independent examiners considering the right and left maxillary sinuses (n=108). There were sinus pathologies on the anterior, medial, lateral and posterior walls, the floor and ceiling of maxillary sinuses, detected with the i-CAT Vision® (version 1.6.20) software. The collected data were correlated with the presence or absence of symptoms related to the sinus pathology. Results: The most frequent tomographic finding was opacification of the sinuses by accumulation of sinusoidal secretions (28.70%), followed by thickening of the antral mucosa of the maxillary sinus (20.37%) and the presence of mucous cyst (17.59%). In 60.22% of the cases, there was no report of clinical symptomatology regardless of the presence of pathology. Simultaneous presence of symptoms and tomographic findings occurred in 35.20% of the sinuses, while in 45.37% there was a tomographic finding without reported symptomatology. The most affected sinus walls were the floor (71.30%), associated with odontogenic origin, and the medial wall (57.40%) associated with upper airway infections. The multiplanar visualization protocol resulted in complete accuracy and sensitivity (100%), followed by the coronal (81.50%) and axial (76%) protocols. Conclusion: Cone beam computed tomography was proven useful for detecting the presence of sinus pathologies, but it was unspecific in the correlation of the findings in symptomatic patients and in the intensity of these symptoms.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Tomography, X-Ray Computed/instrumentation , Cone-Beam Computed Tomography/instrumentation , Maxillary Sinus/pathology , Maxillary Sinus/diagnostic imaging , Brazil , Chi-Square Distribution
3.
Rev. odontol. Univ. Cid. Sao Paulo ; 21(1)jan.-abr. 2009. ilus, tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-532084

ABSTRACT

Introduction: The present study investigates the relationship between respiratory patterns and mandibularmorphology. Methods: The study sample comprised 100 pre-orthodontic patients ranging from 8 to 13years of age. The subject sample was evaluated by clinical examination and lateral cephalometric radiographs.A clinical examination of respiratory patterns categorized the subjects as mouth breathers (GroupM, n=52) and nasal breathers (Group N, n=48). Results: The Student t test revealed a statistically signifi-cant relationship (p<0.05) between Group M and deep antegonial notch and greater lower anterior facialheight. Conclusions: The results of this study suggest that deep mandibular antegonial notch and verticallydirected growth pattern are more prominent in individuals who are mouth breathers


Introdução: Este estudo investiga o relacionamento entre os padrões respiratórios e a morfologia. Métodos:A amostra do estudo foi formada de 100 pacientes pré-ortodônticos cuja idade variou de 8 a 13 anos. Aamostra foi avaliada através de exame clínico e das radiografias cefalométricas laterais. Um exame clínicodos padrões respiratórios categorizou os sujeitos entre aqueles que são respiradores bucais (Grupo M,n=52) e respiradores nasais (Grupo N, n=48). Resultados: O teste t de Student revelou um relacionamentoestatisticamente significativo (p<0.05) entre o Grupo M e o ponto antegonial profundo e uma altura facialanterior mais baixa. Conclusões: os resultados deste estudo sugerem que o ponto antegonial profundo e opadrão de crescimento direcionado verticalmente são mais proeminentes em indivíduos que são respiradoresbucais

4.
Rev. dent. press ortodon. ortopedi. facial ; 12(4): 99-106, 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-460931

ABSTRACT

OBJETIVO: o objetivo desta pesquisa foi avaliar a precisão e acurácia (validade) de medidas cefalométricas lineares em imagens reconstruídas em terceira dimensão (3D), pela técnica de volume, a partir da tomografia computadorizada (TC) multislice. METODOLOGIA: o material da pesquisa consistiu de 10 (dez) crânios secos, previamente selecionados, sem distinção de etnia ou gênero, os quais foram submetidos à TC multislice 16 cortes com 0,5mm de espessura por 0,3mm de intervalo de reconstrução. Posteriormente, os dados obtidos foram enviados para uma estação de trabalho independente, contendo o programa Vitrea®. Os pontos cefalométricos (n=13) foram localizados e as respectivas medidas ósseas lineares (n=15) foram realizadas por 2 examinadores, previamente treinados, medindo cada um duas vezes, independentemente, em 3D. As medidas físicas foram obtidas por um terceiro examinador, utilizando um paquímetro digital. A análise dos dados foi realizada mediante um estudo comparativo entre as medidas inter e intra-examinadores, em 3D-TC, e entre estas e as medidas físicas obtidas diretamente nos crânios, utilizando ANOVA (análise de variância). RESULTADOS: não foram encontradas diferenças estatisticamente significantes entre os valores das medidas inter e intra-examinadores, nem entre as medidas físicas e em 3D, com p>0,6 para todas as medidas. O erro percentual foi de 2,05 por cento para as medidas interexaminadores e de 2,11 por cento para as medidas intra-examinadores. A média do erro percentual entre as medidas físicas e em 3D variou de 0,96 por cento a 1,47 por cento. CONCLUSÃO: todas as medidas cefalométricas lineares foram consideradas precisas e acuradas utilizando a técnica de volume em 3D por meio da TC multislice.


AIM: To test the precision and accuracy of conventional linear cephalometric measurements in 3D reconstructed images using a multislice CT. METHODS: The study population consisted of 10 dry skulls, previously selected, without distinction of ethnic group and sex, which were submitted to a multislice CT 16 slices using 0.5mm of slice thickness and 0.3mm of interval of reconstruction. Subsequently the data was sent to an independent workstation. Conventional craniofacial landmarks (n=13), usually applied to facial orthopedic and orthodontic treatment planning, were localized and linear measurements (n=15) were obtained by 2 radiologists, twice each, independently, in 3D-CT images. In total 600 measurements were made. The correspondent physical measurements were obtained by a third examiner using a digital caliper. Statistical evaluation of the measurements was carried out regarding to inter and intra-examiner, in 3D-CT, and between image and physical measurements from dry skulls, using analysis of variance. RESULTS AND CONCLUSIONS: There were no statistically significant differences between inter and intra-examiner measurements or between imaging and physical measurements. The results also showed an inter-examiner variability error of 2.05 percent, and an intra-examiner variability error of 2.11 percent. There were also no statistically significant differences between imaging and physical measurements with p>0.6 for all measurements. The mean difference was from 0.96 percent to 1.47 percent for all measurements. The validity of linear cephalometric measurements was established using 3D volume rendering from a multislice CT with high precision and accuracy.


Subject(s)
Cephalometry , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL